HOME > Products > Sea Water Source Heat Pump (IWSK-55C,53C series)
* Specification ofSea Water Heat Source Heat Pump (IWSK-55C, 53C series)
Model
|
IWSK-55C-54
|
IWSK-55C-59
|
IWSK-55C-64
|
IWSK-53C-55
|
IWSK-53C-70
|
IWSK-53C-75
|
||
KITECH
|
IJS-50SES
|
IJS-SD200
|
IJS-SD230
|
IJS-SDW195
|
IJS-56SDW
|
|||
Capacity
|
Heating
|
KW
|
189.1
|
205.69
|
224.9
|
192.9
|
244.23
|
261.86
|
USRT
|
53.78
|
58.5
|
63.96
|
54.86
|
69.46
|
74.47
|
||
Cooling
|
KW
|
172.5
|
190.67
|
211.4
|
120.4
|
187.04
|
207.5
|
|
USRT
|
49.06
|
54.22
|
60.12
|
34.24
|
53.19
|
59.01
|
||
Heating/cooling
|
KW
|
29.10/37.07
|
29.78/38.77
|
38.90/48.17
|
30.68/34.10
|
38.38/45.73
|
37.94/40.95
|
|
Power Supply
|
3Phase x 380V x 60Hz
|
|||||||
Refrigeration Cycle
|
Single
|
Dual
|
Single
|
Dual
|
Single
|
|||
Dimension
|
Length
|
mm
|
2,600
|
2,600
|
2,600
|
2,600
|
2,600
|
2,600
|
Height
|
1,870
|
1,870
|
1,870
|
1,870
|
1,870
|
1,870
|
||
Depth
|
1,900
|
1,900
|
1,900
|
1,900
|
1,000
|
1,000
|
||
Compressor
|
Type & Quantity
|
Screw x 1
|
||||||
Driving Method
|
Y-Δ
|
|||||||
Volume Control
|
%
|
0~100%
|
||||||
Refrigeration Ton
|
RT
|
17.35
|
19.38
|
|||||
Refrigerant
|
Type
|
R-407C
|
||||||
Control Method
|
Thermostatic expansion valve
|
|||||||
Heat
Exchanger at Load-side |
Type
|
Coaxial type
|
||||||
Circulation Volume
|
LPM
|
500
|
600
|
600
|
500
|
Heating:750
|
800
|
|
Cooling:600
|
||||||||
Piping(IN/OUT)
|
A
|
100
|
||||||
Heat
Exchanger at Heat source-side |
Type
|
Coaxial type
|
Titanium Tube type
|
|||||
Circulation Volume
|
LPM
|
600
|
700
|
700
|
600
|
Heating:850
|
800
|
|
Cooling:800
|
||||||||
Piping(IN/OUT)
|
A
|
100
|
80/150
|
|||||
Control
|
Temperature Control
|
4way proportional control valve
|
||||||
Operation Control
|
PCB
|
|||||||
Weight
|
kg
|
1,600
|
1,700
|
1,700
|
1,500
|
1,200
|
1,600
|
|
Requirements for certified product
|
heating
|
Inlet of heat exchanger at load-side to be 15°C;
Inlet of heat exchanger at heat source-side to be 15°C |
||||||
cooling
|
Inlet of heat exchanger at load-side to be 25°C;
Inlet of heat exchanger at heat-source-side to be 25°C |
■ The above performance data have been obtained from an official certification institution (KITECH), and may vary depending on the conditions of the installation site.