HOME > Products > Air Source Heat Pump (IAT-16A-01, IAH-16A-05)
* Air Source Heat Pump Water Heater (IAT-16A-01)
EVI Air Source Heat Pump (IAH-16A-01)
Model
|
IAT-16A-01
|
IAH-16A-05
|
|||
Capacity
|
Heating
|
KW
|
2.8
|
17
|
|
Kcal/h
|
2,408
|
14,620
|
|||
USRT
|
0.79
|
4.83
|
|||
Power Consumption
|
KW
|
0.88
|
6.8
|
||
Power Supply
|
1P * 220V * 60Hz
|
3P * 380V * 60Hz
|
|||
Dimension
|
Length
|
mm
|
568
|
1,108
|
|
Height
|
1,670
|
1,075
|
|||
Depth
|
568
|
568
|
|||
Compressor
|
Type
|
Scroll type
|
EVI Scroll type | ||
Quantity
|
1
|
1 | |||
Driving Method
|
Direct-on-line
|
||||
Volume Control
|
%
|
0~100%
|
|||
Refrigerant
|
Type
|
R-410A
|
|||
Control Method
|
Thermostatic expansion valve
|
||||
Condenser
|
Type
|
Brazed Plate type
|
|||
Circulation Volume
|
LPM
|
1.1
|
5.1
|
||
Piping(IN/OUT)
|
A
|
20
|
25
|
||
Outdoor unit
|
Type
|
Finned Copper Tube Type
|
|||
Thermal Storage Area
|
m2
|
0.36
|
1.09
|
||
Fan & Motor
|
Air
Volume |
m3/min
|
8.3
|
83
|
|
Size
|
Ø
|
153
|
460
|
||
Tank Capacity
|
L
|
190L built-in type(STS)
|
Separate installation
|
||
Control
|
Temperature Control
|
Auto inlet/outlet temp control
|
|||
Operation Control
|
PCB
|
||||
Defrosting
|
Hot Gas
|
||||
Weight
|
kg
|
67
|
200
|
||
Conditions for the products
|
heating
|
Outdoor (DB20°C, WB15°C); Temp of water supply to be 15°C; Temp of output water to be 55°C
|
Outdoor (DB7°C, WB6°C); Temp of water supply to be 7°C; Temp of output water to be 55°C; T=48°C
|
■ The above specification may vary depending on the site and temperature conditions.